Shenzhen MingHon Motor Co., Ltd.

Shenzhen MingHon Motor Co., Ltd. China Motor manufacturer.

Manufacturer from China
Active Member
14 Years
Home / Products / Stepper Motor Drivers /

CW5045 24V - 50V DC 1.3A - 4.5A 2 Phase Mirco Stepping Stepper Motor Drivers

Contact Now
Shenzhen MingHon Motor Co., Ltd.
City:shenzhen
Province/State:guangdong
Contact Person:Ms. Wang
Contact Now

CW5045 24V - 50V DC 1.3A - 4.5A 2 Phase Mirco Stepping Stepper Motor Drivers

Ask Latest Price
Video Channel
Supply Ability :1,000,000 / month
Payment Terms :TT,Advance 30%, 70% paid before shipment
Delivery Time :7-30Days
Packaging Details :Standard Export Packing
Price :Negotiable
MOQ :20pcs
Model Number :CW5045
Certification :CE、ROHS
Brand Name :MingHon
Place of Origin :Shenzhen,China(Mainland)
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

CW5045 24V - 50V DC 1.3A - 4.5A 2 Phase Mirco Stepping Stepper Motor Drivers


Characteristics:
1.DC power input type:24V~50VDC
2.Output current:1.3A-4.5A
3.Mircostepping:1(1.8º) 1/2 1/4 1/8 1/16 1/32 1/64 1/128 1/256
1/5 1/10 1/25 1/50 1/125 1/250
4.Protect form :Overheated protect, lock automatic half current ,error connect protect
5.Dimensions:118mm×76mm×33mm
6.Weight:<300g.
7.Working environment:Temperature-15~40℃Humidity<90.

I/O Ports:
1.VCC+:DC power positive pole
Note:Must guard against exceeding 50V, so as not to damage the module
2.GND:DC power cathode
3.A+ A-:Stepping motor one winding
4.B+ B-:Stepping motor other winding
5.PUL+ PUL -:Stepping pulse input+5V (Rising edge effective,rising edge duration >10μS)
6.DIR + DIR-:Stepping motor direction input, voltage level touched off,high towards, low reverse
7.ENA+ ENA-: motor free

NOTE:
1.When ambient temperature is high or working current over 2.7A, fix the module on big metal shell , or use axle flows fan dispels the heat, to make the module run reliably for a long time.
2.Half current automatically: if control machine not send out signal in half second, driver enter half current state of automatically for electricity saving, the phase current of the winding of the electric
3.The fault phase is protected: When the double-phase electrical machinery is connected with driver, users are apt to connect the phase by mistake, thus would damage the driver seriously. The protecting circuit is within this driver, when users connect by mistake, the driver will not be damaged, but the electrical machinery runs abnormally, shake , and output is small.Please check whether the wiring of electrical machinery is a mistake.

Switch Choice: (“ON=0,OFF=1”)

1.Microstepping choice:

SW5

0

0

0

0

0

0

0

0

1

1

1

1

1

1

SW6

0

1

0

1

0

1

0

1

0

1

0

1

0

1

SW7

0

0

1

1

0

0

1

1

0

0

1

1

0

0

SW8

0

0

0

0

1

1

1

1

0

0

0

0

1

1

Micro

1/2

1/4

1/8

1/16

1/32

1/64

1/128

1/256

1/5

1/10

1/25

1/50

1/125

1/250


2.Current choice:

SW1

0

1

0

1

0

1

0

1

SW2

0

0

1

1

0

0

1

1

SW3

0

0

0

0

1

1

1

1

Current(A)

1.3

1.8

2.3

2.7

3.2

3.7

4.2

4.5

3.Full current or half current choice:
SW4:0=Full current,1=half current

4.Pulse choice:
In the driver has a jump

5.installation dimension

Inquiry Cart 0